BugZero found this defect 481 days ago.
This hotfix adds limited compatibility with VMware Cloud Director 10.5 for backup and restore functionalities to Veeam Backup & Replication 12. Before installing this hotfix, please confirm that you are running Veeam Backup & Replication 12 P20230718. You can check the installed build number in the Veeam Backup & Replication Console's Main Menu (≡) under Help > About.
A backup server fails to connect to a server running VMware Cloud Director 10.5 with the error: This VMware Cloud Director server does not support SDK of the following versions
Cloud Director CDP failback to a different location fails with the error: Failed to execute task for VM Id Veeam Plug-in for VMware Cloud Director does not support Cloud Director 10.5, even with the compatibility patch installed.
Verify that Veeam Backup & Replication is running build 12.0.0.1420 P20230718. Ensure no active tasks are occurring. Close the Veeam Backup & Replication Console. Execute the Hotfix Installer on the Veeam Backup Server.
download hotfix KB4489-veeam_backup_12.0.0.1420_PrivateFix_TF557346.zip Updated: 2023-08-29 MD5: 29E738BB6BD388007187A4DA7C0A13EC SHA1: FFDE8E55694503F193893CDEA91EFFCE75B7BD46