Cisco - Defect ID: CSCul97423

5.1.2 : SNMP query on entityMIB fails on asr9k with powered down LC

Last updated on 12/15/2023

Overall
66.0
Severity
6.46.4
Lifecycle
9.19.1
Popularity
3.73.7

Vendor details

  • No defect details.

General

mibd_entity going to mutex while retry redundancy role type on LC which are not supported and LC was down, it causing delay in sysmgr because unsupported redundancy nodes.

Symptom

mibd_entity going to mutex mibd_entity init taking morethan 30 sec, so the syslogs will display on the console. snmpd[1119]: %SNMP-SNMP-3-OID_SUBTREE_MISSING : snmp agent is missing part of oid list in the tree

Conditions

LC & SP down in show platforms

Workaround

Wait to apply snmp configs untils LC & SP cards are up.

Further Problem Description

card_type other than RP/SC/DRP doesn't support redundancy role on standby node.