Symptom #1: RP/0/RP0/CPU0:Feb 25 00:44:57.277 GMT: canb-server[152]: %PLATFORM-CANB_SERVER-7-CBC_PRE_RESET_NOTIFICATION : Node 0/0/CPU0 , Power Sequencer Failure (0x09000000) Symptom #2: RP/0/RSP0/CPU0:Apr 4 11:43:35.845 : canb-server[153]: %PLATFORM-CANB_SERVER-7-CBC_PRE_RESET_NOTIFICATION : Node 0/RSP1/CPU0 , DB Power Failure (0x0f000000)
Symptom #1: RP/0/RP0/CPU0:Feb 25 00:44:57.277 GMT: canb-server[152]: %PLATFORM-CANB_SERVER-7-CBC_PRE_RESET_NOTIFICATION : Node 0/0/CPU0 , Power Sequencer Failure (0x09000000) Symptom #2: RP/0/RSP0/CPU0:Apr 4 11:43:35.845 : canb-server[153]: %PLATFORM-CANB_SERVER-7-CBC_PRE_RESET_NOTIFICATION : Node 0/RSP1/CPU0 , DB Power Failure (0x0f000000)
Do you see the messages indicated in symptom #1 on reload(location all) of the ASR9000 series router or after OIR of a linecard ? If YES, then the fix of CSCux24553 can help by refreshing the power sequencers. We support the recovery of the following cards: A9K-RSP440-TR/A9K-RSP440-SE ASR-9900-RP-TR/ASR-9900-RP-SE ASR-9912-SFC110/ASR-9922-SFC110 A9K-MOD80-TR/A9K-MOD80-SE A9K-MOD160-TR/A9K-MOD160-SE A9K-24X10GE-TR/A9K-24X10GE-SE A9K-36X10GE-TR/A9K-36X10GE-SE A9K-1X100GE-SE/A9K-1X100GE-TR A9K-2X100GE-SE/A9K-2X100GE-TR A9K-8X100GE-LB-TR/A9K-8X100GE-LB-SE A9K-8X100GE-TR/A9K-8X100GE-SE A9K-4X100GE-TR/A9K-4X100GE-SE A9K-400G-DWDM-TR Symptom #2 applies to RSP440 and RP1 and is not fixed via CSCux24553. If Symptom #1 is seen on a card already UP or XR-RUN state, then CSCux24553 cannot fix the issue but provides additional debug ability. Below command reads the power sequencer faultlog for the above supported PIDs run pwrseq faultread 0 0
There are no workarounds.
The "Power Sequencer Failure" error may be an indication of a HW or SW failure. This fix applies only to Power sequencer failures observed during boot-up. Line cards that fail to boot due to a SW issue will be restored with this fix and will boot successfully. This fix does not address any power sequencer failure observed during runtime.