Cisco - Defect ID: CSCva64078

esd restart on NCS5500 due to fdb flush failure

Last updated on 12/15/2023

Overall
66.0
Severity
6.46.4
Lifecycle
9.19.1
Popularity
3.73.7

Vendor details

  • No defect details.

Symptom

System messages similar to the following are observed on the NCS5500: RP/0/RP0/CPU0:fretta16s-002#0/FC5/ADMIN0:Jul 12 11:16:29.624 : esd[1881]: %PKT_INFRA-FM-3-FAULT_MAJOR : ALARM_MAJOR :SWITCH_FDB_ERR_E :DECLARE :0/FC5/FC_SW: 0/FC5/ADMIN0:Jul 12 11:16:29.624 : esd[1881]: %INFRA-ESD-3-SWITCH_FDB_FAILURE : A forwarding database (FDB) operation failure was detected on the FC-SW control ethernet switch. In order to recover, the switch will be reset and the Ethernet Switch Driver process will restart 0/RP0/ADMIN0:Jul 12 11:16:29.997 : esdma[3805]: %PKT_INFRA-FM-4-FAULT_MINOR : ALARM_MINOR :ESDMA lost connectivity with ESD :DECLARE :0/FC5/FC_SW: 0/FC5/ADMIN0:Jul 12 11:16:29.767 : pm[1842]: %INFRA-Process_Manager-3-PROCESS_RESTART : Process esd (IID: 0) restarted 0/RP0/ADMIN0:Jul 12 11:16:38.819 : esdma[3805]: %PKT_INFRA-FM-4-FAULT_MINOR : ALARM_MINOR :ESDMA lost connectivity with ESD :CLEAR :0/FC5/FC_SW:

Conditions

This behavior is timing dependent. The Ethernet Switch Driver process (ESD) occasionally flushes (clears) the Control Ethernet Switch's Forwarding Database (FDB) when it determines a need to clear stale FDB entries. There is a small window of time where this error can occur during the flush operation.

Workaround

There is no workaround for this behavior. No action is required by the user when this error occurs. The ESD process recovers from this error by resetting the Control Ethernet Switch and restarting itself (the ESD process).

Further Problem Description

When this error occurs, the Control Ethernet Switch is reset and the ESD process is restarted. When the switch is reset, the links on all switch ports will go down. As a result, the switch or endpoint at the remote end of any active links will select a redundant path in order to maintain Control Ethernet Connectivity.