Symptom
FMs of Nexus9500 in ACI mode may become unrecoverable-error status after changing Diag Level of FM to full and reboot
spine1 # show module
Mod Ports Module-Type Model Status
--- ----- ----------------------------------- ------------------ ----------
4 36 36p 40G Ethernet Module N9K-X9736PQ ok
21 0 Fabric Module N9K-C9508-FM unrecoverable-error
22 0 Fabric Module N9K-C9508-FM unrecoverable-error
23 0 Fabric Module N9K-C9508-FM unrecoverable-error
24 0 Fabric Module N9K-C9508-FM unrecoverable-error
25 0 Fabric Module N9K-C9508-FM ok
26 0 Fabric Module N9K-C9508-FM ok
27 0 Supervisor Module N9K-SUP-A active
29 0 System Controller N9K-SC-A active
30 0 System Controller N9K-SC-A standby
Conditions
Nexus9500
ACI version:12.2(2f),12.1(2e)
Workaround
this situation is recoverable by following step
1. revert Diag Level of FM from "Full Tests" to "Recommended Tests"
2. erase config of Nexus9500 by "setup-clean-config.sh" and reboot
just erase config and reboot Nexus9500 recover this but if it is rebooted again the issue may happen again
Further Problem Description