Symptom
While testing storm control using bits per second it was notice the counters within the show storm do not match the show interface. This causes inconsistent test results where storm control activates below traffic threshold.
Further Problem Description
920-4SZ-3#show int ten 0/0/3
TenGigabitEthernet0/0/3 is up, line protocol is up
Hardware is 2xGE-4x10GE-FIXED, address is a023.9f88.0883 (bia a023.9f88.0883)
Description: Connection to IXIA 4/6
MTU 9000 bytes, BW 10000000 Kbit/sec, DLY 10 usec,
reliability 255/255, txload 1/255, rxload 1/255
Encapsulation ARPA, loopback not set
Keepalive set (10 sec)
Full Duplex, 10000Mbps, link type is auto, media type is SFP-SR
output flow-control is unsupported, input flow-control is on
ARP type: ARPA, ARP Timeout 04:00:00
Last input never, output never, output hang never
Last clearing of "show interface" counters 00:00:51
Input queue: 0/375/0/0 (size/max/drops/flushes); Total output drops: 0
Queueing strategy: fifo
Output queue: 0/40 (size/max)
30 second input rate 8000 bits/sec, 11 packets/sec <<<< NOT VALURE @ 8000 bps
30 second output rate 0 bits/sec, 0 packets/sec
573 packets input, 57300 bytes, 0 no buffer
Received 573 broadcasts (0 IP multicasts)
920-4SZ-3#
920-4SZ-3#
920-4SZ-3#sho storm-control broadcast
Interface Type Filter State Upper Lower Current
--------- ------ ------------- ----------- ----------- ----------
Te0/0/3 Bcast Forwarding 20k bps 10k bps 10.56k bps <<<<< NOTE WRONG VALUE
920-4SZ-3#