During the upgrade from version 7.1.2 -> 7.4.1 "N540-ACC-SYS" an error has been encountered with the FPGA firmware on the PSU's RP/0/RP0/CPU0:acc1.hac14.lon#show hw-module fpd Tue May 24 10:07:04.672 UTC Auto-upgrade:Enabled FPD Versions ============== Location Card type HWver FPD device ATR Status Running Programd ----------------------------------------------------------------------------------------- 0/RP0 N540-ACC-SYS 1.1 MB-MIFPGA CURRENT 0.05 0.05 0/RP0 N540-ACC-SYS 1.1 Bootloader CURRENT 1.13 1.13 0/RP0 N540-ACC-SYS 1.1 CPU-IOFPGA CURRENT 0.07 0.07 0/RP0 N540-ACC-SYS 1.1 MB-IOFPGA CURRENT 0.23 0.23 0/PM0 N540-PWR400-D 1.256 LIT-PriMCU-DCFW UPGD FAIL 0.04 0.04 0/PM0 N540-PWR400-D 1.256 LIT-SecMCU-DCFW UPGD FAIL 0.06 0.06 0/PM1 N540-PWR400-D 1.256 LIT-PriMCU-DCFW UPGD FAIL 0.04 0.04 0/PM1 N540-PWR400-D 1.256 LIT-SecMCU-DCFW UPGD FAIL 0.06 0.06 From the logs: 0/RP0/ADMIN0:May 23 12:53:59.137 UTC: envmon[3119]: %INFRA-FPD_Driver-1-UPGRADE_ALERT : FPD 0/PM1-LIT-SecMCU-DCFW@0/PM1 image programming completed with UPGD FAIL state Info: [FW transfer failed CRC mismatch. exp 0x3db6 != rcvd 0x7658 blk:1] "LiteOn PSU Firmware Upgrade support does not exist on 741 version / NCS 540 (Tortin) platform. The enhancement support is present for 732 , 742 , 751 which are newer versions , so in order to upgrade the firmware , one of these versions should be used"
When trying to upgrade power-module it fails with the following error: 0/RP0/ADMIN0:Jun 8 08:47:32.500 CEST: fpdserv[3826]: %INFRA-FPD_Manager-1-UPGRADE_ALERT : Upgrade for the following FPDs has been committed: 0/RP0/ADMIN0:Jun 8 08:47:32.500 CEST: fpdserv[3826]: %INFRA-FPD_Manager-1-UPGRADE_ALERT : Location FPD name Force 0/RP0/ADMIN0:Jun 8 08:47:32.500 CEST: fpdserv[3826]: %INFRA-FPD_Manager-1-UPGRADE_ALERT : ================================================== 0/RP0/ADMIN0:Jun 8 08:47:32.501 CEST: fpdserv[3826]: %INFRA-FPD_Manager-1-UPGRADE_ALERT : 0/PM0 LIT-SecMCU-DCFW FALSE 0/RP0/ADMIN0:Jun 8 08:47:32.501 CEST: fpdserv[3826]: %INFRA-FPD_Manager-1-UPGRADE_ALERT : 0/PM0 LIT-PriMCU-DCFW FALSE 0/RP0/ADMIN0:Jun 8 08:47:32.510 CEST: shelf_mgr[2676]: %INFRA-SHELF_MGR-4-ACTION_NOT_SUPPORTED : Card 0/PM0 doesn't support requested action 'HW_LOCK' 0/RP0/ADMIN0:Jun 8 08:47:32.516 CEST: envmon[2614]: %PKT_INFRA-FM-3-FAULT_MAJOR : ALARM_MAJOR :Power Group redundancy lost :DECLARE :0: 0/RP0/ADMIN0:Jun 8 08:47:36.202 CEST: envmon[2614]: %INFRA-FPD_Driver-1-UPGRADE_ALERT : FPD 0/PM0-LIT-SecMCU-DCFW@0/PM0 image programming completed with UPGD FAIL state Info: [FW transfer failed CRC mismatch. exp 0x3db6 != rcvd 0x7658 blk:1] 0/RP0/ADMIN0:Jun 8 08:47:38.237 CEST: envmon[2614]: %INFRA-FPD_Driver-1-UPGRADE_ALERT : FPD 0/PM0-LIT-PriMCU-DCFW@0/PM0 image programming completed with UPGD FAIL state Info: [FW transfer failed CRC mismatch. exp 0x76c != rcvd 0xc956 blk:0] 0/RP0/ADMIN0:Jun 8 08:47:38.238 CEST: shelf_mgr[2676]: %INFRA-SHELF_MGR-4-ACTION_NOT_SUPPORTED : Card 0/PM0 doesn't support requested action 'HW_UNLOCK'
This is expected behavior, and this will not cause any impact, the FPD, LiteOn PSU Firmware Upgrade support does not exist on 741 version, The enhancement support is present from next releases.
NONE