Symptom
A Cisco Nexus9000 C9364C-GX Chassis may experience a reload following a Golden EPLD upgrade. If the EPLD has already been upgraded and is not necessary, performing the unnecessary golden upgrade results in the device timing out and reloading with a Fatal Module Error.
N9K-C9364C-GX# install epld bootflash:[epld-image] module all golden
...
The switch will be reloaded at the end of the upgrade
Do you want to continue (y/n) ? [n] y
Proceeding to upgrade Modules.
Starting Module 1 EPLD Upgrade
Module 1 : MI FPGA [Programming] : 100.00% ( # of # sectors)
EPLD process seems to have exited unexpectedly 2700
Unable to communicate with the EPLD Process
Reloading Supervisor Module 1
...
Last reset at [USECS] usecs after [DATE]
Reason: Reset Requested due to Fatal Module Error
System version: [IMAGE]
Service:
Conditions
Executing A Golden EPLD upgrade CLI on a Nexus C9364C-GX.
N9K#install epld bootflash:[EPLD image] module all golden
Workaround
There is no workaround known at this time.
Further Problem Description
If the Golden EPLD upgrade is not supported or is not required, the software should print a CLI message, "Golden upgrade not supported" or "Golden upgrade not required". The device should not crash.
Please refer to the Cisco Nexus 9000 Series FPGA/EPLD Upgrade Release Notes.