Symptoms
How do I configure bootstrap email notifications in NetWorker 9
Cause
In NetWorker version 9.0 some of the notification resources have moved into a property (field) of Policy, Workflow, Action resource.This is the case for the email bootstrap notification. An example on how to configure this using the new method is shown below.For further details on Notifications within NetWorker 9 please review KB article 478660 NetWorker 9.0 General Discussion Notifications
Resolution
The bootstrap are now configured from the Server Protection PolicyUnder Server Protection policiesEdit the WorkflowEdit Actions: Server db backup until you get to the 'Specify Advanced options' section. There you should add the relevant email command i.e. smtpmail -s "Server Bootstrap" -h 'your mail server' -p 25 'email address'Output will then be received similar to the following for your bootstrap records in case of a recovery scenario;
-----Original Message-----From: SYSTEM@test.serverSent: 07 September 2016 16:06To:Customer@test.serverSubject: Server Protection ---Server backup Action report---Policy name:Server ProtectionWorkflow name:Server backupAction name:Server db backupAction status:succeededAction start time:09/07/16 16:06:04Action duration:0 hours 0 minutes 17 seconds--- Successful Server backup Save Sets --- 4056952030/1473260766 networker2.test.server: index:networker2.test.server level=1, 2 KB, 2 files 4023397610/1473260778 networker2.test.server: bootstrap level=full, 208 KB, 156 files--- Bootstrap backup report --- date time ssid volume device access info 06/09/2016 10:00:15 4274947487 networker2.test.server.001 AdvFileDev1 C:\AdvFileDev1 07/09/2016 10:00:16 4224702240 networker2.test.server..001 AdvFileDev1 C:\AdvFileDev1 07/09/2016 15:50:42 4174391619 networker2.test.server..001 AdvFileDev1 C:\AdvFileDev1 07/09/2016 15:51:47 4124060035 networker2.test.server..001 AdvFileDev1 C:\AdvFileDev1 07/09/2016 15:55:32 4073728612 networker2.test.server..001 AdvFileDev1 C:\AdvFileDev1 07/09/2016 16:06:18 4023397610 networker2.test.server..001 AdvFileDev1 C:\AdvFileDev1