BugZero found this defect 695 days ago.
Following IPv4 database load message is present in /var/log/ltm: 015c0010:5: Initial load of IPv4 Reputation database has been completed Note the absence of: 015c0010:5: Initial load of IPv6 Reputation database has been completed Some scenarios would result in elevated TMM CPU utilization, for example, when using IPI in global policy.
Any of the following: - TCL error results when IPI is used in an iRule resulting in connection being reset. - When using IPI in global policy, increased TMM CPU utilization may occur which leads to idle enforcer being triggered, TMM clock advanced messages appearing in LTM logs, or TMM restarting without core when MCPD is unable to communicate with TMM.
Failure to download IPv6 database from localdb-ipv6-daily.brightcloud.com.
Ensure that BIG-IP is able to communicate using https with BrightCloud servers, including localdb-ipv6-daily.brightcloud.com. For more detailed troubleshooting steps, see K03011490 at https://my.f5.com/manage/s/article/K03011490. Once the IPv6 reputation database has been retrieved and loaded issues should stop. This line in ltm log shows load has completed: 015c0010:5: Initial load of IPv6 Reputation database has been completed
None
9.85
VCMP guest on version 16.1.4 or above might experience constant TMM crashes.9.45
Install fails as lind keeps failing due to "Fatal error: block id new probe failed - device file:/dev/cdrom"9.45
Incomplete or missing IPv6 IPI database results to connection reset and/or high TMM CPU usage9.45
For E810 100G SR-IOV NICs, traffic disruption is seen with ICE driver v1.11.14 and NVM 4.20 combination.9.4
EPVA related dma-agent crash9.85
VCMP guest on version 16.1.4 or above might experience constant TMM crashes.9.85
Global search and other queries fail if BIG-IQ system in an high availability (HA) configuration use IPv6 discovery addresses9.85
BIG-IQ high availability (HA) peer unavailable for a few minutse approximately once a day9.85
Configuration pages might show a banner indicating that import conflicts must be resolved, but links to incorrect device9.85
Menu visibility issue with newly activated license.