BugZero updated this defect 139 days ago.
Fixed an issue where GlobalProtect IPSec tunnels disconnected at half the inactivity logout timer value.
GP tunnel goes down every 30minutes
Because of local time handling difference in MP and DP for a GP tunnel timeout feature, NGFW mistakenly disconnects GP tunnel.
To sync time for this, power off the fw then power up. NOT reboot.
8.95
Fixed a memory leak issue in the mgmtsrvr process that resulted in an OOM condition.8.95
Fixed an issue where the firewall unexpectedly rebooted with the log message "Heartbeat failed previously"8.95
Fixed an issue where GlobalProtect IPSec tunnels disconnected at half the inactivity logout timer value.8.95
Fixed an issue where inserting the NPC and DPC on slot2 created excessive logs in the `bcm.log file`.8.95
Fixed an issue with firewalls in HA configurations where ARP and IPv6 multicast packets were transmitted from the passive firewall.