BugZero updated this defect 157 days ago.
Fixed an issue where configuration changes made in Panorama and pushed to the firewall were not reflected on the firewall.
Config push fails
When service groups have a tag then during processing there is logical error which results in error during validation of the service group
Enable the Share unused object from panorama setting - may cause significant increase the config size OR Remove tags from the service group objects - if they use tags elsewhere, it will impact. The above workarounds might not be feasible - it would depend on the config
8.95
(PA-1400 Series firewalls only) Fixed an issue where, when an HSCI interface was used as an HA2 interface, HA2 packets were intermittently dropped on the passive firewall, which caused the HA2 connection to flap due to missing HA2 keepalive messages.8.95
Fixed an issue where tabs in the ACC such as Network Activity Threat Activity and Blocked Activity did not display data when you applied a Time filter of Last 15 Minutes, Last Hour, Last 6 Hours, or Last 12 Hours, and the data that was displayed with the Last 24 Hours filter was not accurate. Reports that were run against summary logs also did not display accurate results.8.95
Fixed an issue where DNS resolution failed for Panorama and firewall plugins if the DNS Server IP was obtained through DHCP.9.2
Fixed an issue where the /opt/panlogs partition reached capacity due to the logdb-quota for the User-ID log folder not being matched.9.2
Fixed an issue where configuration changes made in Panorama and pushed to the firewall were not reflected on the firewall.