P2V conversion of a Windows server fails at 1% You see the error:An error occurred during the conversion In the converter-worker.log file, you see similar entries related to bad blocks:2012-03-07T13:35:00.461-06:00 [07376 error 'task-4'] BlockLevelVolumeCloneMgr::ReadAndSkipBadBlocks(): Error (type: 2, code: 2) reading 110592 bytes starting at 0x000000018b0dc000 from the source volume E:2012-03-07T13:35:00.461-06:00 [07376 error 'task-4'] BlockLevelVolumeCloneMgr::ReadAndSkipBadBlocks(): Unrecoverable error (type: 2, code: 2) reading 110592 bytes starting from 0x000000018b0dc000 from the source volume E:2012-03-07T13:35:00.461-06:00 [07376 error 'task-4'] BlockLevelVolumeCloneMgr::CloneVolume: failed with exception converter.fault.FileIOFault In the converter agent logs, you see entries similar to:[#2] [2011-09-11 23:30:57.681 03680 info 'task-1'] BlockLevelVolumeCloneMgr::InitCloningPassType: not an incremental clone, and we are not tracking changes for the next iteration, so this must be a standard full clone.[#2] [2011-09-11 23:30:57.681 03680 info 'task-1'] BlockLevelVolumeCloneMgr::CloneVolume: cloning volume with ID \WindowsBitmapDriverVolumeId=[44-4D-49-4F-3A-49-44-3A-CC-58-E6-A1-BD-F2-D7-11-9E-F6-80-6E-6F-6E-69-63][#2] [2011-09-11 23:30:57.681 03680 info 'task-1'] BlockLevelVolumeCloneMgr::CloneVolume: Source volume is mounted under the name\\.\GLOBALROOT\Device\HarddiskVolumeShadowCopy1\[#2] [2011-09-11 23:30:57.681 03680 error 'task-1'] [LiveDeviceReaderWriter] CreateFile(\\.\GLOBALROOT\Device\HarddiskVolumeShadowCopy1) failed with error code 2[#2] [2011-09-11 23:30:57.681 03680 error 'task-1'] SingleVolumeCloneTask::DoRun: Volume cloning failed with error converter.fault.FileIOFault In the Event Viewer of the source physical machine, you see events similar to:Event ID: 14Source: VolSnapType: ErrorDescription The shadow copies of volume <volume> were aborted because of an IO failure on volume <volume>.Event ID: 35Source: dmioType: WarningDescription dmio: Disk Harddisk 1 block 32391 (mountpoint <drive letter>:); Uncorrectable read error
This issue may occur if the hard disk contains hard bad blocks that cannot be fixed using the chkdsk command or if the disks need a defragmentation.
To resolve this issue: Analyze and defragment the physical hard disk using Disk Defragmenter. If the hard disk has hard bad blocks, contact the hardware vendor of the physical server for further assistance.
Windows サーバの P2V 変換が 1% の時点で失敗するWindows 服务器的 P2V 转换在完成 1% 时失败