Performing a vMotion of a virtual machine fails with the errors: Timed out waiting for migration start request The operation is not allowed in the current state In the hostd.log file, located at /var/log/, you see entries similar to: YYYY-MM-DDT18:05:57.413Z [3E057B90 info 'vm:/vmfs/volumes/datastorename/VM1/VM1.vmx'] Disconnect check in progress. YYYY-MM-DDT18:05:57.413Z [3DF03B90 verbose 'Vmsvc.vm://vmfs/volumes/datastorename/VM1/VM1.vmx'] VMotionLastStatusCb: Failed with error 4: Timed out waiting for migration start request. YYYY-MM-DDT18:05:57.424Z [3DF03B90 info 'Hostsvc.HaHost'] vmxSwapEnabled = true vmmOvhd.anonymous: 22964 vmmOvhd.paged: 63957 vmmOvhd.nonpaged: 13771 YYYY-MM-DDT18:05:57.424Z [3DF03B90 info 'Hostsvc.HaHost'] vmkOvhd.fixd = 303104 vmkOvhd.variable: 2050 vmkOvhd.selfSwap: 3145728 YYYY-MM-DDT18:05:57.424Z [3DF03B90 info 'Hostsvc.HaHost'] Computed from lib overhead: 150466560 for (memPages: 524288, fbSize: 2048, #vcpus: 2, #lsiscsi: 1, #pvscsi: 0, #passthru: 0, #network: 1) vmkOverhead: 7647232 YYYY-MM-DDT18:05:57.424Z [3DF03B90 info 'Hostsvc.HaHost'] overhead result (no CBRC): 158113792 YYYY-MM-DDT18:05:57.424Z [3DF03B90 info 'Hostsvc.HaHost'] Predicted overhead: 158113792 for (memory: 2147483648, video: 8388608, #vcpus: 2, autodetect: false, enable3D: false, svgaPtFbSize: 8388608, cbrcOverhead: 0 YYYY-MM-DDT18:05:57.424Z [3DF03B90 verbose 'Vmsvc.vm:/vmfs/volumes/datastorename/VM1/VM1.vmx'] Time to gather config: 11 (msecs) YYYY-MM-DDT18:05:57.425Z [3DF44B90 verbose 'Hbrsvc'] Replicator: ReconfigListener triggered for config VM 44 YYYY-MM-DDT18:05:57.431Z [3DF03B90 verbose 'Vmsvc.vm:/vmfs/volumes/datastorename/VM1/VM1.vmx'] VMotionLastStatusCb:: hostlog state changed from emigrating to failure YYYY-MM-DDT18:05:57.431Z [3DF03B90 verbose 'Vmsvc.vm:/vmfs/volumes/datastorename/VM1/VM1.vmx'] VMotionResolveCheck: Operation in progress YYYY-MM-DDT18:05:57.431Z [3DF44B90 verbose 'Hbrsvc'] Replicator: VmReconfig ignoring VM 44 not configured for replication YYYY-MM-DDT18:05:57.432Z [3DF44B90 info 'Snmpsvc'] VmConfigListener: vm state change received, queueing reload request YYYY-MM-DDT18:05:57.433Z [3E1DCB90 warning 'Default'] Can't convert IP Address of type 0 YYYY-MM-DDT18:05:57.433Z [3DF03B90 verbose 'Vmsvc.vm:/vmfs/volumes/datastorename/VM1/VM1.vmx'] VMotionStatusCb: Completed YYYY-MM-DDT18:05:57.433Z [3DF03B90 verbose 'Vmsvc.vm:/vmfs/volumes/datastorename/VM1/VM1.vmx'] VMotionResolveCheck: Firing ResolveCb YYYY-MM-DDT18:05:57.433Z [3DF03B90 info 'Vcsvc.VMotionSrc (1388772268136447)'] ResolveCb: VMX reports needsUnregister = false for migrateType MIGRATE_TYPE_VMOTION YYYY-MM-DDT18:05:57.433Z [3DF03B90 info 'Vcsvc.VMotionSrc (1388772268136447)'] ResolveCb: Failed with fault: (vmodl.fault.SystemError) { dynamicType = <unset>, faultCause = (vmodl.MethodFault) null, reason = "Timed out waiting for migration start request. ", msg = "", } In the hostd.log file, located at /var/log/, you see entries similar to: YYYY-MM-DDT18:04:27.536Z [4FA40B70 info 'Vcsvc.VMotion' opID=57C757C9-000004C9-9c-75-89 user=vpxuser] InitiateDestination [1388772268136447], VM = '/vmfs/volumes/datastorename/VM1/VM1.vmx' YYYY-MM-DDT18:04:27.536Z [4FA40B70 info 'Vimsvc.TaskManager' opID=57C757C9-000004C9-9c-75-89 user=vpxuser] Task Created : haTask-ha-folder-vm-vim.Folder.registerVm-95992205 YYYY-MM-DDT18:04:27.536Z [4FA40B70 info 'Solo.HaVMFolder' opID=57C757C9-000004C9-9c-75-89 user=vpxuser] Register called: []/vmfs/volumes/datastorename/VM1/VM1.vmx YYYY-MM-DDT18:04:27.544Z [4E040B70 verbose 'Default' opID=9348D6C9-0000017D user=root] AdapterServer: target='vmodl.query.PropertyCollector:ha-property-collector', method='waitForUpdates' YYYY-MM-DDT18:04:27.647Z [4FA40B70 verbose 'Vmsvc' opID=57C757C9-000004C9-9c-75-89 user=vpxuser] Queued registering virtual machine /vmfs/volumes/datastorename/VM1/VM1.vmx YYYY-MM-DDT18:04:27.647Z [4E040B70 verbose 'Vmsvc'] Initializing registering virtual machine [51]: /vmfs/volumes/datastorename/VM1/VM1.vmx YYYY-MM-DDT18:04:27.650Z [4E040B70 info 'vm:Vix: [34103 foundryPollWorker.c:624]: FoundryPollWorker_AssignVMToWorker: Assign VM:/vmfs/volumes/datastorename/VM1/VM1.vmx'] to worker 4E640B70. YYYY-MM-DDT18:04:27.653Z [4E640B70 info 'vm:/vmfs/volumes/datastorename/VM1/VM1.vmx'] Reloading config state. YYYY-MM-DDT18:04:27.668Z [4E640B70 info 'Libs'] VMHS: Transitioned vmx/execState/val to poweredOff YYYY-MM-DDT18:04:27.693Z [4E040B70 verbose 'Default'] SetVmHandle /vmfs/volumes/datastorename/VM1/VM1.vmx 3145898 YYYY-MM-DDT18:04:27.693Z [4E040B70 info 'Vmsvc.vm:/vmfs/volumes/datastorename/VM1/VM1.vmx'] Upgrade is required for virtual machine, version: 7 YYYY-MM-DDT18:04:27.694Z [4E040B70 info 'Vmsvc.vm:/vmfs/volumes/datastorename/VM1/VM1.vmx'] Snapshot tree refresh ignored because the disk access is not enabled. YYYY-MM-DDT18:04:27.695Z [4E040B70 warning 'Vmsvc.vm:/vmfs/volumes/datastorename/VM1/VM1.vmx'] PopulateCache failed: _diskAccess : false, _storageAccessible : true YYYY-MM-DDT18:04:27.696Z [4E040B70 verbose 'Vmsvc.vm:/vmfs/volumes/datastorename/VM1/VM1.vmx'] Get shared vigor fields translated error to vim.fault.GenericVmConfigFault YYYY-MM-DDT18:04:27.696Z [4E040B70 info 'Vmsvc.vm:/vmfs/volumes/datastorename/VM1/VM1.vmx'] Get shared vigor fields failed: vim.fault.GenericVmConfigFault YYYY-MM-DDT18:04:27.696Z [4E040B70 verbose 'Vmsvc.vm:/vmfs/volumes/datastorename/VM1/VM1.vmx'] Get shared vigor fields message: CPUID register value () is invalid. CPUID register value () is invalid. CPUID register value () is invalid. CPUID register value () is invalid. YYYY-MM-DDT18:04:27.696Z [4E040B70 info 'Vmsvc.vm:/vmfs/volumes/datastorename/VM1/VM1.vmx'] Error encountered while retrieving configuration. Marking configuration as invalid: vim.fault.GenericVmConfigFault YYYY-MM-DDT18:04:27.696Z [4E040B70 verbose 'Vmsvc.vm:/vmfs/volumes/datastorename/VM1/VM1.vmx'] Fault Tolerance state callback received YYYY-MM-DDT18:04:27.696Z [4E040B70 verbose 'Vmsvc.vm:/vmfs/volumes/datastorename/VM1/VM1.vmx'] Record/replay state callback received YYYY-MM-DDT18:04:27.696Z [4E040B70 verbose 'Vmsvc.vm:/vmfs/volumes/datastorename/VM1/VM1.vmx'] Skipped tools version initialization as the VM's disk access is not enabled YYYY-MM-DDT18:04:27.697Z [4E040B70 info 'Vmsvc.vm:/vmfs/volumes/datastorename/VM1/VM1.vmx'] State Transition (VM_STATE_INITIALIZING -> VM_STATE_OFF) YYYY-MM-DDT18:04:27.697Z [4E040B70 verbose 'Vmsvc.vm:/vmfs/volumes/datastorename/VM1/VM1.vmx'] Max connection count changed from 0 to 40 YYYY-MM-DDT18:04:27.698Z [4E040B70 info 'Vmsvc.vm:/vmfs/volumes/datastorename/VM1/VM1.vmx'] Initialized virtual machine. YYYY-MM-DDT18:04:27.701Z [4E040B70 info 'Vmsvc.vm:/vmfs/volumes/datastorename/VM1/VM1.vmx'] Marking VirtualMachine invalid YYYY-MM-DDT18:04:27.701Z [4E040B70 info 'Vmsvc.vm:/vmfs/volumes/datastorename/VM1/VM1.vmx'] State Transition (VM_STATE_OFF -> VM_STATE_INVALID_CONFIG) YYYY-MM-DDT18:04:27.701Z [4E040B70 verbose 'Hostsvc.HostConfigSyncManagerImpl'] Sync called YYYY-MM-DDT18:04:27.701Z [4E040B70 verbose 'Hostsvc.HostConfigSyncManagerImpl'] Scheduling '/sbin/backup.sh' in 5 seconds (backup counter = 0) YYYY-MM-DDT18:04:27.702Z [4E040B70 verbose 'Hostsvc.ResourcePool ha-root-pool'] Added child 51 to pool YYYY-MM-DDT18:04:27.702Z [4E040B70 info 'Vimsvc.ha-eventmgr'] Event 250 : Registered Unknown 36 on mtaspesx4.mta.mdot.mdstate in ha-datacenter YYYY-MM-DDT18:04:27.702Z [4E040B70 warning 'Default'] Complete Task: task haTask-ha-folder-vm-vim.Folder.registerVm-95992205 not registered as started YYYY-MM-DDT18:04:27.702Z [4E040B70 info 'Vimsvc.TaskManager'] Task Completed : haTask-ha-folder-vm-vim.Folder.registerVm-95992205 Status success YYYY-MM-DDT18:04:27.708Z [FFD5BB70 verbose 'Default' opID=9348D6C9-0000017E user=root] AdapterServer: target='vmodl.query.PropertyCollector:session[43831e05-bc42-7082-620c-a24c0da54260]5268e62e-6cca-eab7-117e-ea9b8e05dd4a', method='waitForUpdates' YYYY-MM-DDT18:04:27.710Z [4F780B70 verbose 'Default' opID=SWI-bfd8bde9 user=vpxuser] AdapterServer: target='vim.ResourcePool:ha-root-pool', method='GetConfig' YYYY-MM-DDT18:04:27.712Z [4E040B70 verbose 'Default' opID=SWI-bfd8bde9 user=vpxuser] AdapterServer: target='vim.ResourcePool:ha-root-pool', method='GetName' YYYY-MM-DDT18:04:27.748Z [4FA40B70 error 'Vmsvc.vm:/vmfs/volumes/datastorename/VM1/VM1.vmx' opID=57C757C9-000004C9-9c-75-89 user=vpxuser] Invalid transition requested (VM_STATE_INVALID_CONFIG -> VM_STATE_IMMIGRATING): Invalid state YYYY-MM-DDT18:04:27.748Z [4FA40B70 warning 'Vcsvc.VMotionDst (1388772268136447)' opID=57C757C9-000004C9-9c-75-89 user=vpxuser] Bind: Failed to initialize VMotionWorker YYYY-MM-DDT18:04:27.748Z [4FA40B70 warning 'Vcsvc.VMotionDst (1388772268136447)' opID=57C757C9-000004C9-9c-75-89 user=vpxuser] Initiate: Bind failed: vim.fault.InvalidState YYYY-MM-DDT18:04:27.748Z [4FA40B70 warning 'Vcsvc.VMotionDst (1388772268136447)' opID=57C757C9-000004C9-9c-75-89 user=vpxuser] Initiate: Unregistering after Bind failure YYYY-MM-DDT18:04:27.748Z [4FA40B70 verbose 'Vmsvc.vm:/vmfs/volumes/datastorename/VM1/VM1.vmx' opID=57C757C9-000004C9-9c-75-89 user=vpxuser] Unregister called on virtual machine
This issue occurs because there are missing cpuid values in the .vmx file located on the virtual machine being vMotioned.
The virtual machine must be powered off to commit the changes to the .vmx file.You can power the machine off and cold migrate it, but future vMotions fail if the changes are not made to the file.Simply editing the file and reloading the virtual machine without powering it off causes the blank entries to be repopulated into the .vmx file once it is reloaded.The .vmx file must be edited to allow future migrations to succeed and it must be powered off temporarily for the change to take effect.
This issue is resolved in ESXi 5.5 Update 2, available at VMware Downloads. For more information, see VMware ESXi 5.5 Update 2 Release Notes.To work around the issue: Make a backup of the .vmx file cp path/filename path/filename.bak. Where path is the full path of the file and filename is the name of the file you wish to edit. Note: Ensure the second parameter in the cp command has a filename with the .bak extension to indicate that it is a backup copy. Locate the cpuid entries in the .vmx file with blank values. For example: cpuid.X.eax = "" cpuid.X.ecx = "" cpuid.X.ecx.amd = "" cpuid.X.edx = "" Note: An X represents a possible numerical value. Power off the machine.With a text editor, remove these entries from the .vmx file. For more information, see Editing files on an ESX host using vi or nano (1020302).Reload the virtual machine. For more information, see Reloading a vmx file without removing the virtual machine from inventory (1026043). Alternatively, unregister and re-register the machine.Power on the virtual machine.Confirm that the entries for the cpuid have been removed from the .vmx file.Perform the vMotion again on the powered on machine.
Editing configuration files in VMware ESXi and ESXEditing files on an ESX host using vi or nanoReloading a vmx file without removing the virtual machine from inventoryvMotion が 14% の時点で失敗し、次のエラーが表示される: 移行開始要求の待機中にタイム アウトになりましたvMotion 在进行到 14% 时失败,并出现错误:等待迁移启动请求时超时