Document Version Release Date Details 2 18 March 2019 In Table 2: changed "P115" to "P137", "P102" to "P129", and deleted the "3.2.1 MU5" row 1 6 September 2018 Original Document Release HPE 3PAR StoreServ Storage hard disk drive (HDD) models that start with "STHB" are approaching their end of life (EOL) and will be discontinued. Spare part numbers for the discontinued STHB drives are transitioning to alternate drive models and spare part numbers listed in Table 1. This advisory outlines how to prepare for this transition. A transition period, extending up to 1 March 2019, is provided to prepare HPE 3PAR StoreServ arrays to accept the new alternate replacement drive models. The majority of HPE 3PAR StoreServ arrays will require only an HPE 3PAR StoreServ OS patch to accept the alternate replacement drive. This is a one-time operation that is done online and will not impact the use or performance of the array. To prepare for this transition, perform the following steps: Identify all HPE 3PAR StoreServ 7000, 8000, 10000, and 20000 arrays with one or more STHB drive installed by using the HPE 3PAR StoreServ Management Console (SSMC) or the following HPE 3PAR CLI command: cli% showpd -i -p -devid STHB0600S5xeN010,STHB1200S5xeN010,STHB1800S5xeN010,STHB1200S5xeF010 For each array with one or more STHB drives installed, refer to Table 2 for a list of required actions, based on the current HPE 3PAR StoreServ OS version and patch level of the array. If needed, based on Table 2, plan and schedule the installation of the appropriate patch and/or the HPE 3PAR StoreServ OS update. HPE 3PAR StoreServ 7000, 8000 and 9000 systems support the option of customers performing OS updates, along with Service Processor (SP) updates, with the exception of SP 4.x to 5.x updates. We urge customers to refer to the relevant update and release note documentation and to carefully review the dependencies of various host environments provided in the information library. If you are not confident in updating or applying patches, contact Global Deployment Services (GDS) as documented below. Link to Information Library: https://www.hpe.com/info/storage/docs/ HPE 3PAR StoreServ 10000 and 20000 systems DO NOT support the customer performing OS updates. Contact the GDS as documented below. Contacting the Global Deployment Services (GDS): Please refer to the following article to request a 3PAR StoreServ OS patch or update: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00061484en_us NOTE : To assist customers with the installation of the alternate drive patches, the HPE Global Deployment Center (GDC) will Auto-Stage the appropriate patches to those HPE-maintained arrays that require them, and where authorized by customers. After the transition period has elapsed, failed STHB drives will be replaced with the newer equivalent alternate drive model, as shown in Table 1. If the array is not at the necessary OS/patch level shown to accept the alternate replacement (refer to Table 2), the patch must be installed prior to the drive replacement. This can lead to a delay in replacing a failed drive on the array and potentially, if multiple drives fail, to data unavailability. If the required patch is already staged on the array, the HPE Customer/Field Engineer can install the patch prior to replacing the drive, thus reducing the overall delay. If the array requires more than a patch (such as an MU or OS update), a plan should be in place to update the array to the appropriate HPE 3PAR StoreServ OS version and patch level prior to 1 March 2019. It is critical to note the following: Beginning 1 March 2019, availability of the original STHB spare part numbers cannot be guaranteed. With a failed drive, an MU or full OS update of the HPE 3PAR StoreServ array can only proceed in an offline manner. Therefore, HPE strongly recommends that HPE 3PAR StoreServ arrays be proactively updated prior to 1 March 2019 to accept the alternate replacement drive models. Table 1 - STHB Alternate Replacement Drives System Model Drive Capacity Encryption EOL Drive Model Number (CLI command: showpd -i) EOL Drive Spare Part Alternate Replacement Drive Model Number Alternate Replacement Spare Part 7000 600GB Not encrypted STHB0600S5xeN010 840456-001 SSKB0600S5xeN010 P03797-001 7000 1200GB Not encrypted STHB1200S5xeN010 840457-001 SSKB1200S5xeN010 P03798-001 7000 1800GB Not encrypted STHB1800S5xeN010 840462-001 SSKB1800S5xeN010 P03799-001 7000 1200GB Encrypted STHB1200S5xeF010 873888-001 SSKB1200S5xeF010 P03800-001 8000 600GB Not encrypted STHB0600S5xeN010 840458-001 SSKB0600S5xeN010 P03797-001 8000 1200GB Not encrypted STHB1200S5xeN010 840459-001 SSKB1200S5xeN010 P03798-001 8000 1800GB Not encrypted STHB1800S5xeN010 840460-001 SSKB1800S5xeN010 P03799-001 8000 1200GB Encrypted STHB1200S5xeF010 875659-001 SSKB1200S5xeF010 P03800-001 10000 600GB Not encrypted STHB0600S5xeN010 844288-001 SSKB0600S5xeN010 P03809-001 10000 1200GB Not encrypted STHB1200S5xeN010 844270-001 SSKB1200S5xeN010 P03810-001 10000 1800GB Not encrypted STHB1800S5xeN010 844285-001 SSKB1800S5xeN010 P03811-001 10000 1200GB Encrypted STHB1200S5xeF010 P01032-001 SSKB1200S5xeF010 P03812-001 20000 600GB Not encrypted STHB0600S5xeN010 840463-001 SSKB0600S5xeN010 P03805-001 20000 1200GB Not encrypted STHB1200S5xeN010 840464-001 SSKB1200S5xeN010 P03806-001 20000 1800GB Not encrypted STHB1800S5xeN010 840465-001 SSKB1800S5xeN010 P03807-001 20000 1200GB Encrypted STHB1200S5xeF010 875658-001 SSKB1200S5xeF010 P03808-001 Table 2 - Action matrix to transition to alternate replacement drive models Current HPE 3PAR StoreServ OS version (CLI command: showversion -b) Required action to accept alternate replacement drive NOTE : Patch numbers may become obsolete by one or more subsequent patches. If so, HPE recommends installing the highest patch number in the chain of obsoleting patches. 3.3.1 MU2 and later No action required 3.3.1 MU1 Apply patch P25 3.2.2 MU6 Apply patch P137 3.2.2 MU4 Apply patch P129 All other OS versions Plan and perform the appropriate update to the HPE 3PAR OS system at your earliest convenience. For HPE 3PAR StoreServ drive support reference documents, release notes, and update documentation, refer to the HPE Storage Information Library: http://www.hpe.com/info/storage/docs
This advisory applies to the following HPE 3PAR Storage products with one or more STHB drive models installed: HPE 3PAR StoreServ 7000 Storage HPE 3PAR StoreServ 8000 Storage HPE 3PAR StoreServ 10000 Storage HPE 3PAR StoreServ 20000 Storage
Ensure each HPE 3PAR StoreServ array, with one or more STHB drives installed, either meets or exceeds the HPE 3PAR StoreServ OS requirements specified in Table 2, or has a plan in place to update the array within the transition period, enabling it to accept the alternate replacement drive model. RECEIVE PROACTIVE UPDATES : Receive support alerts (such as Customer Advisories), as well as updates on drivers, software, firmware, and customer replaceable components, proactively in your e-mail through HPE Subscriber's Choice. Sign up for Subscriber's Choice at the following URL: Proactive Updates Subscription Form