When email notifications are configured with Managed Logs Enabled on HPE MSA 1040, 2040, and 2042 arrays running GL225R003 or later firmware, an Event 400 email may be received that is reported as an Unknown Event.
Here is an example of the Event 400 email:
Event:
Unknown event (400). errorCode=0 param1=12=0xc param2=0=0x0 param3=0=0x0 param4=0=0x0
EVENT ID:
EVENT CODE:400
EVENT SEVERITY:Informational
Event 400 is reporting a Informational-level event where the managed logs have reached a level at which it should be archived. The Event log will report the following for the above event:
INFORMATIONAL Managed logs: A log region has reached the level at which it should be archived. (region: MC debug, region code: 12)
Scope
This advisory applies to the following HPE MSA Storage arrays:
HPE MSA 1040 SAN Storage
HPE MSA 2040 SAN Storage
HPE MSA 2042 SAN Storage
Resolution
This is a informational event and can be safely ignored.