Info
Document Version
Release Date
Details
2
February 23, 2022
Updated Resolution with permanent fix, OneView 6.40
1
November 8, 2021
Original document release
On Superdome Flex 280 servers running firmware version 1.20.x and using OneView version 6.30 or earlier, the create and reapply operations will fail when managing BIOS settings using the OneView server profile.
Scope
The issue occurs under both of the following circumstances:
On HPE Superdome Flex 280 servers running firmware version 1.20.x
When managing BIOS settings using the server profile feature in OneView 6.30 or earlier versions.
Resolution
On systems running OneView 6.30 or earlier that upgrade the firmware to HPE Superdome Flex 280 firmware version 1.20.x, follow the below instructions:
Do not use the OneView server profile feature to manage BIOS settings. Alternatively, use the RMC web interface or CLI to manage BIOS settings.
Upgrade to OneView V6.40 as OneView 6.40 and later will support OneView server profile feature to manage BIOS settings.
The latest version of HPE OneView can be found
here
RECEIVE PROACTIVE UPDATES
: Receive support alerts (such as Customer Advisories), as well as updates on drivers, software, firmware, and customer replaceable components, proactively in your e-mail through HPE Support Alerts. Sign up for Support Alerts at the following URL:
HPE Email Preference Center