BugZero updated this defect 34 days ago.
Fixed an issue where enabling Inline Cloud Analysis caused the content and threat detection (CTD) process flow cleanup to not be done correctly if a threat was encountered during the traffic inspection.
Multiple cores result in dataplane instability and unexpected reboots.
Enabling Inline Cloud Analysis leads to a freed content and threat detection process flow getting accessed.
Disable Inline Cloud Analysis.From CLI,set profiles spyware <name> cloud-inline-analysis noset profiles url-filtering <name> cloud-inline-cat no
8.95
Fixed an issue where the dataplane restarted repeatedly after a reboot due to an internal path monitoring failures until a power cycle.8.95
Fixed an issue where the firewall unexpectedly rebooted with the log message "Heartbeat failed previously"8.95
Fixed an issue where GlobalProtect IPSec tunnels disconnected at half the inactivity logout timer value.9.7
Fixed an issue where sessions were dropped with the message `resource-unavailable` due to the content inspection queue filling up.8.95
Fixed an issue where upgrades remained at 71%, which caused the firewall to stop responding until it was manually power cycled.8.95
Fixed an issue where the dataplane restarted repeatedly after a reboot due to an internal path monitoring failures until a power cycle.8.95
Fixed an issue where the firewall unexpectedly rebooted with the log message "Heartbeat failed previously"8.95
Fixed an issue where GlobalProtect IPSec tunnels disconnected at half the inactivity logout timer value.9.7
Fixed an issue where sessions were dropped with the message `resource-unavailable` due to the content inspection queue filling up.8.95
Fixed an issue where upgrades remained at 71%, which caused the firewall to stop responding until it was manually power cycled.