BugZero found this defect 1638 days ago.
The NetWorker Management Console (NMC) Monitoring window shows all policies as "Never Run" ; however, backup and clone jobs completed as per schedule.The following error appears in the NMC when trying to retrieve workflow details from the Monitoring tab: Message bus unable to open socket connection to host "Networkerserver_hostname" on port 5672: a socket error occurred NetWorker server is 19.5 or older. Port 5672 is the non-SSL port used by the message queue process. Newer versions of NetWorker use SSL port 5671.
A firewall is blocking port 5671.
NetWorker: How to disable port 5672 for DSA-2018-120, to avoid scanning software still showing the vulnerabilityOpen port 5671 on your NetWorker server operating system or network firewall. Once the firewall allows this port, the NMC reports the correct information in the Monitoring window.NetWorker Processes and PortsThe rabbitmq process on the NetWorker server uses port 5671. The NetWorker processes use this port/service to relay information between each other and present them in the NetWorker user interfaces. See operating system vendor instructions for creating firewall rules; The system/security administrator must make these changes. Once changes are applied to the operating system firewall, confirm if port 5672 connectivity succeeds between the NetWorker server and NMC server. If the connection still fails, ensure that a network firewall is not blocking the communication.